2: DS54 - Switch addresses set by board address and are consecutive in groups of four. Option Switch 08-Startup Delay and Power Management Issues. This forum is so helpful. To reset DCS52, DCS210 or DCS240 close Option Switch 40. So I should have active detection on three sections. Anotheralternative would be to use the Atlas Snap Relay. That makes me think that either you didn't actually close OpSw 6, or something (maybe another throttle, or a macro?) Programming The Digitrax DS64 & Other Options - YouTube A: Yes you can power the DS64 using any of the 3 options. Watched your video, and noticed you said you changed "Switch 1" to closed (at about 4:20). However, for purposes of estimation: Twelve Locomotives. By k9jri in forum DCC Replies: 7 Last Post: 14th Nov 2016, 02:28 PM. MP5 Advanced Model Railway Turnout / Switch Motor and Digitrax DS64 I don't see an obvious isolation between the 2 visible blocks. The plastic junk ones always result in problems as they crimp fron an angle. Reverse Loops2. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and How To Set Up Routes Using Your DS64NOTE: During this procedure the DS64 must be connected to an active LocoNet with an active command station.1. Technically speaking! Member . manage your account online and more! I haven't put either item back 'on-line' yet so for the time being, I'll assume the problem has been taken care of. And make sure the contact area of the BDL is clean - there should be obvious marks from the edge connector if you look at it. Keep Good Records:Although it may seem to be a pain while setting up your Digitrax system, keeping layout records Copyright 2023 Digitrax, Inc. All Rights Reserved. These units were designed to have theFRONT jack's second Railsync differential signal run as a diode-or'ed power source (for throttles). Here is a discription of my hardware and software conections. This tool may access a particular DS64 by entering the Board ID number in the selection box at the top of the window. The factory default setting for all DB150 option switches is t or "thrown" The Initial Procedure 1. While I was at it I returned the PS14 that died shortly after buying it (the cost of shipping the PS14 back by itself wasn't economically practical). K. k4kfh . It is also possible for the DS64 to get it's power from the track hooked to Trk A and Trk B terminals, but experience has proven that this power source may not be reliable in certain situations. Is this possible? But the OP didn't ask how many switch inputs there are, he asked if you can control a single turnout with multiplepush buttons: So my answer stands: Simply connect the two (or more) momentary pushbuttons in parallel. On the DS64 press and hold the OPS button down for about 3 seconds until How To Run a Route with DS64:1. Or, without having to create a logon and open a ticket, you can simply go to the DS74 product page and read the doc to get your answers. Unless of course insulated joiners are used. 2 TEAMYAKIMA Members 3.3k Posted June 23, 2022 I regret that I am still getting problems with DIGITRAX (in general) even though tens of thousands of people around the world rave about the brand. Did you try reprogramming the address associated with the 4 outputs to see if that fixes the issue ? If you are experiencing this behavior then you need to add one or more PS14s to provide enought power for the DS64s you have connected. The Digitrax DS54 accessory decoder can be configured in a large number of ways (DecoderPro can help with that). This is because we put a constant square wave AC current on the track and control the trains (locos) by sending messages to them (actually to receivers we call decoders) to tell them what to do such as start, stop, change directions, etc. Thanks,fmilhaupt. If you have tried resetting the DS64 by closing Option Switch 7 and that has not worked for you, please try resetting the Digitrax system (DCS50/51, DB150 or DCS100/200) by closing Option Switch 39. KB152: DS64 - Troubleshooting - Digitrax How are you powering the DS64? Track power is used to supply loco power only. The DS64 is a powerful stationary decoder. When using more than one DS64 in a DCC environment, you must assign a Board ID to each additional DS64 so that each one has a unique Board ID.You will need to set the DS64's board ID if you are planning to use the DS64's 8 inputs with a computer, system throttle, or other smart device on your layout that needs to know when a turnout has been manually thrown or closed via a particular DS64.You can use the 8 inputs on the DS64 to control the operation of the 4 outputs that control your turnouts. OpSw 03 = Closed, the pulse width is 400ms. With a wall plug or through your track power? A: Each DS54 CV must be manually reconfigured to set the DS54 to factory default values. Problems with a Digitrax DS64 - Model Railroader Magazine - Model The slip switch is a track element that has both a crossing at grade and also a set of movable points which allow trains to both cross another track and also change track. I have an old Diamond Scale turntable; this turntable uses a rotary switch to select which stall or track you want to align the table with. Connect the DS64s TRKA and TRKB terminals to your track. Specifically today with a DS74. Digitrax DS64 and JMRI - DCC, Electrical & Automation - JNS Forum This document outlines the power requirements for Digitrax LocoNet accessories. Well, it really doesn't matter much with only a single booster connected. Unless you do a lot of work to ensure that there is absolutely no way that the edge connector can shift either way and thereby prevent its contacts from shorting two pads on the Tortoise, you run the risk of the connector shifting and shorting across the track power and DS64 output pad. A: The AR1 is handles correcting the track polarity mismatch when a reversing section is encountered by a locomotive. We will use independent turnout addresses to demonstrate the flexibility that the DS64 offers. The DS64 is strictly looking for power, and doesn't need the DCC signal from the track to set op-switches. The first situation is where one of the many advanced features offered by the LocoNet and the various LocoNet compatible devices is desired to be used on a layout Switch Mode is used for sending commands to accessory decoders and for changing Option Switches (OpSw) in your DCS50. You can configure all of the options, and assign the switch addresses for each port on the DS64 with this. http://wabashcolumbiabranch.blogspot.com/. Digitrax sent replacements for both items. This article was last updated on Jan. 10, 2012, 5:46 p.m. | Print Article | Leave Feedback. BD4 Features: Cost Effective occupancy detection for 4 detection sections Reply IowaDCC LocoNet is the conduit for information outside of a specific DS64, including external devices controlled by a particular DS64. The DS64 works with a wide selection of hardware. If so, is there a fix other than a trip back to the creator? The rail B from the DCS50 is connected to the far rail on my test track. Has anyone here experienced this type of problem with a DS64? OpSw 02, 03, 04, &05 closed would give me a 3 second pulse. If the DS64 looses the addresses, then no matter what you send it, the outputswill stay where they power on. Determines The Type of Turnouts You Can OperateOpSw 01 defines the output type (static or pulse) for the decoder. Is that correct? In addition to the route You can automate grade crossing signal lights with block occupancy sensors. I am also going to email Digitrax support to see if they have any suggestions. It is also possible for the DS64 to get it's power from the track hooked to Trk A and Trk B terminals, but experience has proven that this power source may not be reliable in certain situations. It seems to be sporadic in that upon power-up some switches are thrown and others aren't. Did you try reprogramming the address associated with the 4 outputs to see if that fixes the issue ? I was looking for a "drop in" replacement solution for the Tortoise which I have already hooked up to Digitrax DS64 DCC Turnout controllers for throttle switch control, as well as panel mounted push-button switches and LED turnout direction indicator lights. For use with bi-polar turnouts in large scale, the DS64 is a better choice. Published sources describe the Fulgurex motor as needing 400 Ma for operation, which is well beyond the capacity of the DS64. You can use the same 12/14v bus to power all your DS64s and DS74s. I am having issues with a Digitrax DS64. The BD1, block occupancy detector (replaced in 2004 by the BD4) was designed as an add-on device, which took advantage of the block occupancy message generating (over the LocoNet) capabilities of the DS54. I'd measure for voltage on the outputs for the track power LED, and see if there's anything there. JMRI Hardware Support - Digitrax LocoNet - Java Model Railroad Interface Make sure the momentary-on push buttons are wired as shown in Fig.1 above. You need to have a tip/ring connector for it though as it doesn't have the 2 header connections for power. Ireland Digitrax Complete Train Control makes reliable, realistic train operation and simplified layout wiring a reality. It's simply a minor curiosity, so minor in fact that I've never even bothered to see if it's only certain outputs, or certain DS64's, or whatever. Please reference the KB article number in your ticket. This allows for adequate current for the switches. Digitrax DS64; Digitrax BDL16, BDL162, and BDL168; Digitrax PM4, PM42; Digitrax SE8C; Digitrax BXPA1; . A power supply or power buss used solely to power multiple DS64s. as switch commands (I'm assuming you're using track power for your DS64's.). Connect the DS64s TRKA and TRKB terminals to your track. It is good that the AR1 controls the switching of the track power for a reverse loop automatically but it seems the turn out direction also needs auto control. Follow this procedure and every cable will be a good one (unless you stick one on upside downa nd make a telco cable by accident). Reply; MrMe. Q: When setting OpSw 1, do I have to be connected to track power or can I power Can a DS64 be powered from the LocoNet RailSync lines? A: One power supply can be used if it can provide adequate power forall the DS64s it is powering. And, of course, if you add a second locomotive, then DCC becomes the clear choice because you are not longer having to throw toggle switches just to move around the yard. The Slip SwitchThe more complex slip switch allows trains to both cross and to change tracks: In the schematic below, you will note that the slip switch is more compact than ordinary turnouts. The jacks on the back of these units are LocoNet Jacks that are used for connecting LocoNet devices to the network. In the pic there are 2 of the 3 shown. This user's group is run by and for Digitrax users. How to Change the Settings of Your Ds64'S Option Switches (Opsw) 11. Many Digitrax LocoNet Kato makes a Unitrack double-crossover, their No. I think I'll stick with the DS64 as the rest of my stuff is all Digitrax and I won't have to reinvent the wheel on learning how to hook it up and program it. Individual turnouts operate by throttle command, routes work with throttle command BUT when route is executed it not only throws the route specific to DS64 #2, it also throws individual turnouts assigned to DS64 #1. Digitrax DS64 power up problem. I have a gap cut in the rail, it is the near rail of my test track. Although it is possible to power the DS64 from track power, this has been a source of problems for many operators due to low voltage. It is basically a closed connection, or relay connection to select the track you want. The PL-10 is a coil-type switch machine with double solenoids. This H0-scale railroad track plan first appeared in the Atlas Model Railroad Company's book "Six Railroads You Can Build", written by John Armstrong and illustrated by Tad Stepek. Posting Permissions You may not post . There are two major situations that would require the PR3 to act as a stand alone LocoNet controller. Digitrax DS64 Power On Quirk. As the number of switches increase, it would be a growing hassle to have to verify and/or realign each switch on the layout each time the power is cycled. KB327 Using the DS64 with internal DSC100 routes When using a DCS100 or DCS200 to setup routes within the Command Station in conjunction with DS64 Stationary Decoders, the DS64 needs to be connected to Track Power.
Bush Hog Spindle Assembly, Lottie London Follow Me Eyeliner Pink, Articles D